Hydrogenated sterilizerWhat do you need to do with maintenance and maintenance?
At present,Hydrogenated sterilizerThe maintenance of the equipment is a relatively complicated work. Many medical institutions have equipment department, responsible for maintaining the safety and stability of the equipment, but there are many problems that many equipment maintenance personnel are not understandable or valued. Here you will never popularize the maintenance and maintenance of medical equipment.
The first point, meticulous daily maintenance, the normal operation of ensuring the equipment and equipment is critical.
Daily maintenance seems simple, but many times is not paid to it, it is also the most easy to ignore; but many times the big problem is often accumulated by small problems. To do actively cooperating with clinical users, keep the surface cleaning; before use, check the voltage, the power supply is normal; pay attention to the function of the instrument is normal and recorded during use. Develop good habits when daily maintenance, avoid damage to the incident.
Second, equipment maintenance work, must be carefully treated, don't be hidden.
When the instrument is faulty, it is necessary to collect information collected before the maintenance; including model, factory number, fault time, there is no abnormal sound in the fault, whether there is a sudden power outage, the instrument has no movement.
It should be noted in the maintenance. In the process of disassembling the medical equipment, pay attention to the order of order, do not use brute force to dismount. The fastening screws, small pieces, etc., etc., etc., to be classified, avoid loss. After the equipment is repaired, when installing, press the opposite order to restore the original, there is no extra accessories. Damaged zero accessories, also have a tag, replacement, and do not have errors.
After the maintenance work is completed, you should clean the surface of the instrument, turn on the power, and see if it can work properly. Correct the instrument to restore normal working status, then give it to the user to see if the instrument restores the original working state to avoid hidden dangers. Finally, clean the scene, check if there is no missing tool, etc., and fill in the maintenance log for detailed view.
When the protective engineer in the maintenance is maintenance instrument, you must pay attention to the protection work, whether it is leakage or cross-infection, pay attention to protection. Do not have unnecessary accidental injuries.
In the third point, regular maintenance check, the problem is discovered as soon as possible, solved as soon as possible.
The detailed preventive maintenance content should include:
Visual inspection outer inspection
Exterior check first check the instrument each button, switch, connector socket, no looseness and misplacedThe contacts of the plug socket have no oxidation, rust or contact, no aging, whether the heat dissipation exhaust is normal, whether the connection of various grounding connectors and pipelines is good.
Clean and maintenance
It is cleaned to the surface of the instrument and the internal electrical part and the mechanical part.Including cleaning the filter and related pipelines, cleaning the instrument's related plug sockets, preventing adverse contact, refueling the necessary mechanical parts.
Replace the loss
Decreased service life and performance, Unqualified components or requirements specified in the User Manual require timely replacement accessories to be replaced in time, preventing possible failures or causing machine failure. The situation of insufficient charging of the battery should urge relevant personnel to perform regular charging, exclude apparent and potential failures.
Function check
Check the indicator light, whether the indicator is normal, By adjusting, set each switch and button, enter each function setting to check if the basic function of the device is normal. Through simulation tests, check whether the various alarm functions of the equipment are normal.
Performance test calibration
Test the voltage regulation values of each DC power supply, test point voltage value or waveform in the circuit and make necessary calibration and adjustment according to the requirements of the bookTo ensure that the instrument has achieved standards to ensure the quality of the instrument in medical diagnosis and treatment.
Security check security check
1. Check that the rack is firm and whether the mechanical operation is normal, and each connecting component has no loosening, falling off or rupture.
2, check the various leads, plugs, connectors, etc. There is no damage, whether the grounding wire is secure, the grounding resistance and the leakage current are within the allowable limit.

Scan it