Hydrogen peroxide sterilizer operation process and precautions

Time:2018-04-08| Author:admin

 
 Hydrogenated sterilizerOperation process and precautions  
 
 Hydrogen peroxide sterilizer operation process  
 
 Open the door to place the metal instrument that requires sterilization, glass instruments (washing and drying);  
 
 First, turn on the power supply;  
 Second, open the sterilizer power switch;  
 Third, close the sterilizer door;  
 
 Select mode: Example (210 degrees) Press 210 or key, then press the confirm key, the sterilization program is turned on;  
 Other items are sterilized as examples, please select a sterilization mode;  
 If a super high temperature alarm occurs during the sterilization process, close the sterilization program or turn off the power switch immediately.  
 
 The cooling system is automatically started after sterilization;  
 
 After about 18 minutes, sterilization is completed, the display shows the sterilization of the sterilization (with a tone), then turn off the power switch, later taking the object;  
 
 Be careful when taking the object.  
 
 Hydrogenated sterilizer  Precautions for use  
 
 1. The hydrogen peroxide sterilizer should be placed in indoor drying and level to prevent vibration and corrosion.  
 
 2. Pay attention to the safe power, install a sufficient capacity of the power slater according to the power consumption power. Choose enough power supply and should have a good ground wire.  
 
 3. The dry thermosacteria cabinet with an electrical point mercury thermometer type thermostat shall separate the two wires of the electrical contact thermometer to the two terminals of the top.  
 Another ordinary mercury thermometer is inserted into the exhaust valve and open the hole of the exhaust valve.  
 Adjusts the molten metal of the electrical point to fasten the screws on the steel cap after the required temperature to achieve the purpose of constant temperature.  
 However, you must pay attention to the adjustment, you must do not indicate the iron to the scale.  
 
 4. When everything is ready to work, you can put the test into the hydrogen peroxide sterilizer, then connect and turn on the power, and the red indicator lights up indicates that the box has been heated.  
 When the temperature reaches the temperature of the temperature, the red light is turned off and the green light is on, and the constant temperature is started.  
 In order to prevent temperature control failure, you must also look at it.  
 
 5. Pay attention to the arrangement that is not too secret when putting the test product.  
 Tests should not be released on the heat dissipation plate to avoid affecting the flow of hot air.  
 Baking baking, explosive, volatile, and corrosive items.  
 
 6. When you need to observe the condition of the working indoor sample, you can open the outer cabinet door and observe through the glass door. But the door is as little as possible to avoid affecting the temperature.  
 Especially when working in more than 200 ° C, the opening box door may cause the glass door to rupture.  
 7. Hydrogen peroxide sterilizer with blast, must turn the blower during heating and constant temperature, otherwise the uniformity of the temperature of the studio temperature and the heating element are damaged.  
 
 8. After the work is completed, turn off the power in time to ensure safety.  
 
 

9. Maintain clean inside and outside the hydrogen peroxide sterilizer.



If you want to know more detailed hydrogen peroxide sterilizer, information
Can call the Kang customer service hotline    

Hotline: 0755-2899-8970 / 17302606088

Tel:0755-2899 8970
Phone:17302606088 / 15112452179
E-mail:zpliu@biodecon.com.cn
Address: 2nd Floor, Building 14, Beiguang Industrial Park, Liangbai Road, Pinghu Street, Longgang District, Shenzhen

Scan it